Communications via IP Networks to any SCADA System (AN98-1) (59KB PDF)
|
| Communications via IP Networks to any SCADA System. |
| |
 |
Configuring DNP3 & MODBUS Over Cellular (91KB PDF)
|
| Configuring DNP3 & MODBUS over cellular. |
| |
 |
Fully Integrated Pump Station Network and Energy Optimization Solution (113KB PDF)
|
| Fully integrated Pump Station Network and Energy Optimization Solution |
| |
 |
Motor Protection (AN23.2) (320KB PDF)
|
| This Application note shows how to set up the MonitorPro to protect motors from overcurrent, undercurrent, locked rotor, phase failure and insulation breakdown. |
| |
 |
Inverter Protection During Insulation Resistance Test (AN24.2) (420KB PDF)
|
| This Application Note shows how to protect inverter outputs from the high voltages generated during an insulation resistance test. |
| |
 |
MonitorPro Security (AN25.2) (182KB PDF)
|
| This Application note shows how to set up the MonitorPro security features. |
| |
 |
Flow Calculations (AN21.2) (160KB PDF)
|
| This application note shows how to configure the MonitorPro to perform flow calculations. |
| |
 |
MonitorPro Manual Cross-Reference (AN41.2) (148KB PDF)
|
| The MonitorPro manual was reorganized in March 2003. Use this Application Note cross-reference sections in older manuals. |
| |
 |
MTISB5 Wiring Diagram (65KB PDF)
|
| MTISB5 Wiring Diagram |
| |
 |
MTISB10 Wiring Diagram (64KB PDF)
|
| MTISB10 Wiring Diagram |
| |
 |
Redundant Level Sensing with the MT2PC (AN73-1) (274KB PDF)
|
| Redundant Level Sensing with the MT2PC using an analog level sensor and a Probe as a backup device. |
| |
 |
Spill Management Using the Peak Levels Function (AN53.1) (147KB PDF)
|
| MultiTrode's MT2PC/MT3PC Family comes with built-in functionality that can be used for managing spills in a much more efficient and safer method than the traditional "hold out" technique. |
| |
 |
MT2PC Pumps not Alternating (AN42.3) (142KB PDF)
|
| This Application Note shows how to solve a mis-configuration issue that results in the pumps not alternating. |
| |
 |
Turning Off Jockey Pumps When a Large Pump Starts (AN34.2) (184KB PDF)
|
| Two small pumps normally control the well, with alternation. If the level gets too high, a third larger pump will turn on. The smaller pumps must be turned off when the large pump starts. |
| |
 |
Selective Lock-out of Pumps (AN35.3) (161KB PDF)
|
| This application note shows how to maximise use of available pumps while selectively locking out other pumps. The example used for this application note is a GenSet that cannot run certain combinations of pumps.
New Version Sump Cleanout (AN42.9)
Multitrode Pump Controllers normally stop the pump-out sequence before the pump reaches the snore point. However, for many sewer wells, it is desirable to completely empty the well on a regular basis. This cleans the well, and reduces problems from odours.
|
| |
 |
Sump Cleaning Function (AN31.2) (184KB PDF)
|
| This Application Note teaches how to get all pumps to periodically run past their normal stopping point in order to clean out the pipes in pre-v7.7 controllers. |
| |
 |
Grit Mixer Control via Pump Controllers (AN22.2) (337KB PDF)
|
| A Grit Mixer is controlled in sequence with the pumps to clean out the bottom of the well each cycle. |
| |
 |
Reducing Odors in Sewer Wells (AN46.2) (261KB PDF)
|
| How to use the "Maximum Off Time" function on MultiTrode's Pump Controllers to reduce odors from stagnant sewer wells. |
| |
 |
Improving Safety at Pump Stations (AN47.2) (250KB PDF)
|
| The MultiTrode Pump Controllers have various features that improve Occupational Health and Safety at site, by giving a visual indication of the well level without the need to open the well, and the ability to simulate levels to test control functions without having to actually fill the well. |
| |
 |
Problems with Excess Station Starts (AN44.2) (226KB PDF)
|
| Most municipal authorities have issues with excess pump station starts. This Application Note shows how to improve the efficiency of pump stations by intelligently limiting station starts. |
| |
 |
Level Sensing Options in the MTxPC (AN74.1) (159KB PDF)
|
| The MTxPC controllers have several options available as level devices, from the MultiTrode Probe, to analog devices such as presure transducers, and even complex combinations of these. This application note describes the options available and how to program the options into the controller.
Software Version Compatibility (AN37.3)
This application note helps the user avoid network problems from incompatablilities. |
| |
 |
Digital Inputs Latching (AN28.2) (135KB PDF)
|
| This Application Note shows how to wire digital inputs. |
| |
 |
Multiple Sites in Close Proximity Sharing a Radio (AN52-1) (375KB PDF)
|
| How to connect multiple controllers in close proximity to one radio. |
| |
 |
Redundant Level Sensing with the MT2PC (AN73-1) (274KB PDF)
|
| Redundant Level Sensing with the MT2PC using an analogue level sensor and a probe as a backup device...
Pump Control Applications
These application notes specifically apply to improving pump control efficiency, or specialist pump control applications.
|
| |
 |
Spill Management using the Peak Levels function (AN53.1) (147KB PDF)
|
| The MultiTrode MT2PC/MT3PC pump controller family comes with inbuilt functionality, which can be used for managing spills, in a much more efficient and much safer method than the traditional "hold out" technique. |
| |
 |
Pumps not Alternating (AN42.3) (142KB PDF)
|
| This application note shows how to solve the common "Fault" that the pumps are not alternating. This is not a fault, merely a mis-configuration issue.
(Version 3 of this Application Note was created to also show the solution for Charge Mode Operation). |
| |
 |
Turning Off Jockey Pumps When a Large Pump Starts (AN34.2) (184KB PDF)
|
| Two small pumps normally control the well, with alternation. If the level gets too high, a third larger pump will turn on. The smaller pumps must be turned off when the large pump starts. |
| |
 |
Selective Lock-out of Pumps (AN35.3) (161KB PDF)
|
| This application note shows how to maximise use of available pumps while selectively locking out other pumps. The example used for this application note is a GenSet that cannot run certain combinations of pumps.
New Version Sump Cleanout (AN42.9)
Multitrode Pump Controllers normally stop the pump-out sequence before the pump reaches the snore point. However, for many sewer wells, it is desirable to completely empty the well on a regular basis. This cleans the well, and reduces problems from odours.
|
| |
 |
Sump Cleaning Function (AN31.2) (184KB PDF)
|
| This Application Note teaches how to get all pumps to periodically run past their normal stopping point in order to clean out the pipes in pre-v7.7 controllers. |
| |
 |
Grit Mixer Control via Pump Controllers (AN22.2) (337KB PDF)
|
| A Grit Mixer is controlled in sequence with the pumps to clean out the bottom of the well each cycle. |
| |
 |
Reducing Odors in Sewer Wells (AN46.2) (261KB PDF)
|
| How to use the "Maximum Off Time" function on MultiTrode's Pump Controllers to reduce odors from stagnant sewer wells. |
| |
 |
Improving Safety at Pump Stations (AN47.2) (250KB PDF)
|
| The MultiTrode Pump Controllers have various features that improve Occupational Health and Safety at site, by giving a visual indication of the well level without the need to open the well, and the ability to simulate levels to test control functions without having to actually fill the well. |
| |
 |
Problems with Excess Station Starts (AN44.2) (226KB PDF)
|
| Most municipal authorities have issues with excess pump station starts. This Application Note shows how to improve the efficiency of pump stations by intelligently limiting station starts. |
| |
 |
Level Sensing Options in the MTxPC (AN74.1) (159KB PDF)
|
| The MTxPC Family has several options available as level devices, from the MultiTrode Probe to analog devices such as presure transducers. This Application Note describes the options available and how to program them. |
| |
 |
Digital Inputs Latching (AN28.2) (135KB PDF)
|
| This Application Note shows how to wire digital inputs. |
| |
 |
Multiple Sites in Close Proximity Sharing a Radio (AN52-1) (375KB PDF)
|
| How to connect multiple controllers in close proximity to one radio. |
| |
 |
PumpView Security & Reliability (175KB PDF)
|
| PumpView Security & Reliability Application Note. |
| |
 |
Communications Cable Connections (154KB PDF)
|
| This Application Note shows the connections required for the communications cables used for modems, radios, laptops, networking, software updates or downloading data logs and settings. |
| |
 |
MTRRM Manual (505KB PDF)
|
| The MultiTrode MTRRM International Manual (A4 Paper). |
| |
 |
Resmon Failover Mode Using Dual-Frequency Radios (AN65.1) (174KB PDF)
|
| The MTRRM Reservoir Monitor has a safety feature whereby, if communications to the CMF are lost, the ResMon will communicate directly with its Slave Pump Stations. When the CMF is communicating again, the ResMon will revert to normal mode.
This Application Note shows how to implement failover mode on a dual-frequency radio network. |
| |
 |
Redundant Level Sensing with the MT2PC (AN73-1) (274KB PDF)
|
| Redundant Level Sensing with the MT2PC using an analog level sensor and a Probe as a backup device. |
| |
 |
Spill Management using the Peak Levels Function (AN53.1) (147KB PDF)
|
| The MultiTrode MT2PC/MT3PC Family comes with built-in functionality that can be used for managing spills in a much more efficient and safer method than the traditional "hold out" technique. |
| |
 |
MT2PC - Pumps not Alternating (AN42.3) (142KB PDF)
|
| This Application Note shows how to solve a mis-configuration issue that results in the pumps not alternating. |
| |
 |
Turning Off Jockey Pumps When a Large Pump Starts (AN34.2) (184KB PDF)
|
| Two small pumps normally control the well, with alternation. If the level gets too high, a third larger pump will turn on. The smaller pumps must be turned off when the large pump starts. |
| |
 |
Selective Pump Lock-Out (AN35.3) (161KB PDF)
|
| This Application Note shows how to maximize use of available pumps while selectively locking out other pumps. |
| |
 |
Sump Cleaning Function (AN31.2) (184KB PDF)
|
| This Application Note teaches how to get all pumps to periodically run past their normal stopping point in order to clean out the pipes in pre-v7.7 controllers. |
| |
 |
Grit Mixer Control via Pump Controllers (AN22.2) (337KB PDF)
|
| A Grit Mixer is controlled in sequence with the pumps to clean out the bottom of the well each cycle. |
| |
 |
Reducing Odors in Sewer Wells (AN46.2) (261KB PDF)
|
| How to use the "Maximum Off Time" function on MultiTrode's Pump Controllers to reduce odors from stagnant sewer wells. |
| |
 |
Improving Safety at Pump Stations (AN47.2) (250KB PDF)
|
| MultiTrode's pump controllers have various features that improve Occupational Health and Safety - by providing a visual indication of the well level without the need to open the well, and the ability to simulate levels to test control functions without having to actually fill the well. |
| |
 |
Problems with Excess Station Starts (AN44.2) (226KB PDF)
|
| Most municipal authorities have issues with excess pump station starts. This Application Note shows how to improve the efficiency of pump stations by intelligently limiting station starts. |
| |
 |
Level Sensing Options in the MTxPC (AN74.1) (159KB PDF)
|
| The MTxPC controllers have several options available as level devices, from the MultiTrode Probe to analog devices such as presure transducers. This Application Note describes the options available. |
| |
 |
Digital Inputs Latching (AN28.2) (135KB PDF)
|
| This Application Note shows how to wire digital inputs. |
| |
 |
Multiple Sites in Close Proximity Sharing a Radio (AN52-1) (375KB PDF)
|
| How to connect multiple controllers in close proximity to one radio. |
| |