<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MultiTrode Blog</title>
	<atom:link href="http://www.multitrode.com/blog/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.multitrode.com/blog</link>
	<description>Pump Station &#38; Lift Station Technology</description>
	<lastBuildDate>Thu, 14 Oct 2010 12:57:16 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.5</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>WEFTEC 2010 &#8211; NEW ORLEANS!</title>
		<link>http://www.multitrode.com/blog/2010/10/weftec-2010-new-orleans/</link>
		<comments>http://www.multitrode.com/blog/2010/10/weftec-2010-new-orleans/#comments</comments>
		<pubDate>Wed, 13 Oct 2010 22:02:23 +0000</pubDate>
		<dc:creator>Adam Rutledge</dc:creator>
				<category><![CDATA[General News]]></category>
		<category><![CDATA[DuoProbe]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[environmental]]></category>
		<category><![CDATA[MultiSmart]]></category>
		<category><![CDATA[probe]]></category>
		<category><![CDATA[pump station]]></category>
		<category><![CDATA[Pump Station Management]]></category>
		<category><![CDATA[Pump Station Optimization]]></category>
		<category><![CDATA[SCADA]]></category>
		<category><![CDATA[WEFTEC]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=821</guid>
		<description><![CDATA[WEFTEC 2010 New Orleans, what a great show!
The show started off in its usual fashion – introductions, leads, demos and apparently for New Orleans little sleep and a lot of people talking about the fun they had the night before.  This year’s WEFTEC was easily surpassed previous years, with over 17,500 people attending and 984 [...]]]></description>
			<content:encoded><![CDATA[<p>WEFTEC 2010 New Orleans, what a great show!</p>
<p>The show started off in its usual fashion – introductions, leads, demos and apparently for New Orleans little sleep and a lot of people talking about the fun they had the night before.  This year’s WEFTEC was easily surpassed previous years, with over 17,500 people attending and 984 exhibitors.  The exhibit hall itself was nearly a mile long end to end.</p>
<p>There was a lot of chatter this year about energy efficiency, sustainability and the wastewater infrastructure. A big ticket issue was the EPA’s new Clean Water and Drinking Water Infrastructure Sustainability Policy. This of course ties right into our philosophy – save operating and energy cost, work towards a sustainable water infrastructure and become greener through conscientiously managing your pump stations more efficiently.</p>
<p>Overall the show was amazing, we had great booth traffic, awesome help from Brendan’s reps &#8211; Coastal and Odessa Pumps, Hydra Service, Automatic Engineering Inc., Pete Duty and Associates, Instrument and Supply, and Nedrow and Associates. And of course our very own MultiTrode crew, Sandy in particular who did a great job organizing and coordinating WEFTEC 2010.  We are looking forward to taking on The City of Angels at WEFTEC 2011!
<a href='http://www.multitrode.com/blog/2010/10/weftec-2010-new-orleans/weftec_2010_7/' title='weftec_2010_7'><img width="150" height="150" src="http://www.multitrode.com/blog/wp-content/uploads/2010/10/weftec_2010_7-150x150.jpg" class="attachment-thumbnail" alt="" title="weftec_2010_7" /></a>
<a href='http://www.multitrode.com/blog/2010/10/weftec-2010-new-orleans/weftec_2010_1/' title='weftec_2010_1'><img width="150" height="150" src="http://www.multitrode.com/blog/wp-content/uploads/2010/10/weftec_2010_1-150x150.jpg" class="attachment-thumbnail" alt="" title="weftec_2010_1" /></a>
<a href='http://www.multitrode.com/blog/2010/10/weftec-2010-new-orleans/weftec_2010_3/' title='weftec_2010_3'><img width="150" height="150" src="http://www.multitrode.com/blog/wp-content/uploads/2010/10/weftec_2010_3-150x150.jpg" class="attachment-thumbnail" alt="" title="weftec_2010_3" /></a>
<a href='http://www.multitrode.com/blog/2010/10/weftec-2010-new-orleans/weftec_2010_5/' title='weftec_2010_5'><img width="150" height="150" src="http://www.multitrode.com/blog/wp-content/uploads/2010/10/weftec_2010_5-150x150.jpg" class="attachment-thumbnail" alt="" title="weftec_2010_5" /></a>
<a href='http://www.multitrode.com/blog/2010/10/weftec-2010-new-orleans/weftec_2010_6/' title='weftec_2010_6'><img width="150" height="150" src="http://www.multitrode.com/blog/wp-content/uploads/2010/10/weftec_2010_6-150x150.jpg" class="attachment-thumbnail" alt="" title="weftec_2010_6" /></a>
<span id="more-821"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/10/weftec-2010-new-orleans/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>MultiTrode at the WIOA Exhibition</title>
		<link>http://www.multitrode.com/blog/2010/10/multitrode-at-the-wioa-exhibition/</link>
		<comments>http://www.multitrode.com/blog/2010/10/multitrode-at-the-wioa-exhibition/#comments</comments>
		<pubDate>Wed, 06 Oct 2010 05:56:20 +0000</pubDate>
		<dc:creator>Norman Pon</dc:creator>
				<category><![CDATA[General News]]></category>
		<category><![CDATA[Industry]]></category>
		<category><![CDATA[MultiTrode News]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=790</guid>
		<description><![CDATA[ 
The 73rd Annual Victorian (WIOA)  Water Industry Engineers &#38; Operators Conference &#38; Exhibition was held at the Bendigo Showgrounds on 2nd and 3rd September 2010. There were 141 exhibitors and over 1000 people attended the exhibition over the two days. There were conference sessions held over the two days allowing delegates to see vendor exhibits [...]]]></description>
			<content:encoded><![CDATA[<p> </p>
<p>The 73rd Annual Victorian (WIOA)  Water Industry Engineers &amp; Operators Conference &amp; Exhibition was held at the Bendigo Showgrounds on 2nd and 3rd September 2010. There were 141 exhibitors and over 1000 people attended the exhibition over the two days. There were conference sessions held over the two days allowing delegates to see vendor exhibits and also attend presentations.<br />
There were Award Presentations for the following:</p>
<p>• Presentation of Actizyme Prizes for “Best paper by WIOA Members”<br />
• Presentation of Hepburn &amp; Iwaki Prizes for “Best Paper Overall”<br />
• Presentation of WITC Prize for “Best Operator Poster Paper”<br />
• Presentation of “Operator of the Year” as judged by AWA (Vic)<br />
• Presentation of “Young Operator of Year” as judged by IWA (Vic)</p>
<p>Our stand was well located and we met existing customers and also potential new customers.  Overall it was worthwhile to exhibit and be seen as it increases awareness of our products and enhances the Multitrode brand. Stuart and myself needed to put the feet up after three days of standing and also the “fun part” setting up and packing up!</p>
<p> </p>
<div><img class="alignleft size-medium wp-image-791" title="WIOA, Bendigo, 2010" src="http://www.multitrode.com/blog/wp-content/uploads/2010/10/WIOA-Bendigo-007-300x225.jpg" alt="WIOA, Bendigo, 2010" width="300" height="225" /></div>
<div> </div>
<div>____________________________________________</div>
<div><img class="alignleft size-medium wp-image-793" title="WIOA Bendigo, 2010" src="http://www.multitrode.com/blog/wp-content/uploads/2010/10/WIOA-Bendigo-008-300x225.jpg" alt="WIOA Bendigo, 2010" width="300" height="225" /></div>
<div>____________________________________________</div>
<div> </div>
<div><img class="alignleft size-medium wp-image-794" title="WIOA, Bendigo, 2010" src="http://www.multitrode.com/blog/wp-content/uploads/2010/10/WIOA-Bendigo-009-300x225.jpg" alt="WIOA, Bendigo, 2010" width="300" height="225" /></div>
<div> </div>
<div>____________________________________________</div>
<div><img class="alignleft size-medium wp-image-795" title="WIOA, Bendigo, 2010" src="http://www.multitrode.com/blog/wp-content/uploads/2010/10/WIOA-Bendigo-013-300x225.jpg" alt="WIOA, Bendigo, 2010" width="300" height="225" /></div>
<div> </div>
<div>      </div>
<div>____________________________________________</div>
<p><span id="more-790"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/10/multitrode-at-the-wioa-exhibition/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Reservoir Monitoring</title>
		<link>http://www.multitrode.com/blog/2010/06/reservoir-monitoring/</link>
		<comments>http://www.multitrode.com/blog/2010/06/reservoir-monitoring/#comments</comments>
		<pubDate>Mon, 07 Jun 2010 17:36:40 +0000</pubDate>
		<dc:creator>Darcy Sullivan</dc:creator>
				<category><![CDATA[General News]]></category>
		<category><![CDATA[MTRRM]]></category>
		<category><![CDATA[pump station]]></category>
		<category><![CDATA[Remote Reservoir Monitor]]></category>
		<category><![CDATA[Reservoir Monitor]]></category>
		<category><![CDATA[Reservoir Monitoring]]></category>
		<category><![CDATA[SCADA]]></category>
		<category><![CDATA[SCADA System]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=787</guid>
		<description><![CDATA[What is a Reservoir?
A reservoir is a body of water collected and stored for community use. A reservoir can be a natural lake or an artificial lake.
Why Do We Need Reservoirs?
The vast majority of Americans rely on centralized water systems for potable water. Centralized water systems typically include:

Watershed &#8211; A Water Source
Collection Point &#8211; Such [...]]]></description>
			<content:encoded><![CDATA[<p><strong><em>What is a Reservoir?</em></strong><strong><em><br />
</em></strong>A reservoir is a body of water collected and stored for community use. A reservoir can be a natural lake or an artificial lake.</p>
<p><strong><em>Why Do We Need Reservoirs?<br />
</em></strong>The vast majority of Americans rely on centralized water systems for potable water. Centralized water systems typically include:</p>
<ul>
<li>Watershed &#8211; A Water Source</li>
<li>Collection Point &#8211; Such as a lake, river, aquifer</li>
<li>Treatment &#8211; Purification and Water Treatment Facilities</li>
<li>Storage &#8211; <span style="text-decoration: underline;">Reservoirs</span>, Storage Tanks, Water Towers, Standpipes</li>
<li>Distribution &#8211; Network of Pipes and Pump Stations</li>
</ul>
<p> <strong><em>What is a Reservoir Monitor?<br />
</em></strong>Centralized water systems consist of hydrologic and hydraulic elements including a Reservoir Monitor. A Reservoir Monitor is a device used to transmit water level information from a Reservoir to a Pump Station.</p>
<p><strong><em>Why is Reservoir Monitoring Important?<br />
</em></strong>Monitoring the level of water in a reservoir is very important to the general population because it influences decisions ranging from water appropriation to agriculture to hydropower generation. In addition, during times of heavy rainfall, water level information is crucial to planning and flood avoidance.</p>
<p>This growing need for optimizing the use and management water can be met by MultiTrode’s Remote Reservoir Monitor (MTRRM), which gathers water level and I/O data from a Reservoir to be used in a Pump Station at a different location.</p>
<p><strong><em>MultiTrode’s Remote Reservoir Monitor (MTRRM)</em><br />
</strong>MultiTrode’s Remote Reservoir Monitor (MTRRM) has two analog inputs, one analogue output, six digital inputs, three digital outputs and an input for monitoring the DC supply voltage. The MTRRM can link to a Pump Station via a SCADA system, or in a stand-alone configuration.</p>
<p>In a SCADA network, the CMF (Central Monitoring Facility) typically makes the decisions on activation of pumps. However, when the CMF is not operational for any reason, the MTRRM and remote Pump Station sense this and transmit in a peer-to-peer configuration, increasing water supply reliability. (When the MTRRM detects that the SCADA system is running again, it will revert back to normal operation via the CMF).</p>
<p>The MTRRM can also be used as a forwarding site for messages from SCADA to other units. This is useful for getting information to sites that cannot communicate directly with the SCADA system.<span id="more-787"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/06/reservoir-monitoring/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Details on MultiSmart Firmware Version 2.3</title>
		<link>http://www.multitrode.com/blog/2010/05/details-on-multismart-firmware-version-2-3/</link>
		<comments>http://www.multitrode.com/blog/2010/05/details-on-multismart-firmware-version-2-3/#comments</comments>
		<pubDate>Fri, 14 May 2010 14:57:33 +0000</pubDate>
		<dc:creator>Darcy Sullivan</dc:creator>
				<category><![CDATA[MultiTrode News]]></category>
		<category><![CDATA[Alternation by Efficiency]]></category>
		<category><![CDATA[data logger]]></category>
		<category><![CDATA[DNP]]></category>
		<category><![CDATA[DNP/MODBUS]]></category>
		<category><![CDATA[DNP3]]></category>
		<category><![CDATA[DuoProbe]]></category>
		<category><![CDATA[IRT]]></category>
		<category><![CDATA[isagraf]]></category>
		<category><![CDATA[Last Known Power Factor]]></category>
		<category><![CDATA[Maintenance Mode]]></category>
		<category><![CDATA[Max Starts]]></category>
		<category><![CDATA[Modbus]]></category>
		<category><![CDATA[Power Factor]]></category>
		<category><![CDATA[Probe Fail Indicator]]></category>
		<category><![CDATA[Probes]]></category>
		<category><![CDATA[Pump Reversal]]></category>
		<category><![CDATA[WITS]]></category>
		<category><![CDATA[WITS-DNP]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=784</guid>
		<description><![CDATA[MultiSmart Firmware version 2.3, incorporates a host of new and unique features in addition to enhancements to current functions providing operations the ability to reach new levels of productivity.]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.multitrode.com/pump-station-manager" target="_blank">MultiSmart </a>Firmware version 2.3, incorporates a host of new and unique features in addition to enhancements to current functions providing operations the ability to reach new levels of productivity.</p>
<p><strong>Impressive new features include:</strong></p>
<ul>
<li><a href="http://www.multitrode.com/blog/2010/05/new-multismart-data-logger-enhancements/" target="_blank"><strong>Data Logger Enhancements</strong> </a>– There are several new Logging Features for Crisis, Interval and Configuration Logging. Interval Logs can optionally trigger DNP events. User interface has been greatly enhanced including saving logs to CF (config logs, IP address, serial number, MAC address, etc) and System Logs (var/log/messages).</li>
<li><strong><a href="http://www.multitrode.com/blog/2010/05/new-alternation-by-efficiency-enhancements-in-multismart-firmware-version-2-3/" target="_blank">Alternation by Efficiency Enhancements</a></strong> – When the efficiency of pumps is within a configurable deadband, standard alternation is used instead of the N to 1 ratio.</li>
<li><strong><a href="http://www.multitrode.com/blog/2010/05/multismart-firmware-2-3-duoprobe-features/" target="_blank">DuoProbe Upgrades</a></strong> – This marks the formal software release for support of the DuoProbe, including enhancements to DuoProbe operation and calibration.</li>
<li><strong>Maintenance Mode</strong> – A timer is now associated with Maintenance Mode. In addition, flow calculations are disabled during Maintenance Mode operation.</li>
<li><strong>Print Out Info Pages to Excel</strong> – With the push of a button, capture a snapshot of all values displayed on the Info Pages and save it to a .csv file, which can then be imported into Excel.</li>
<li><strong>Last Known Power Factor</strong> – This innovative tag reflects the last known power factor: You no longer need to wait until the pump starts in order to determine the power factor.</li>
<li><strong>Generations of DNP/MODBUS Log Files</strong> – The size of the protocol logs are now programmable with a configurable number of file generations. These logs can help troubleshoot communications issues.</li>
<li><strong>Pump Starts/Stops Independent of Level</strong> – This clever feature allows custom logic to take full control of pumps and is designed especially for PID applications.</li>
<li><strong>Probe Fail Indicator</strong> – The number of the failed sensor is now indicated which helps isolate Probe problems and reduce the amount of time it takes to troubleshoot the problem.</li>
<li><strong>WITS-DNP</strong> – This involves enhancements to DNP3 mandated by the UK water industry. There are some features which have been designed in a generic way so that they can be used outside of WITS. Exposure outside of WITS is scheduled for a future release.</li>
</ul>
<p><strong>Other notable improvements include:</strong></p>
<ul>
<li><strong>Restart MultiSmart Tag</strong></li>
<li><strong>Disable a Running ISaGRAF Program</strong></li>
<li><strong>Pump Reversals</strong></li>
<li><strong>Single Sensor and Three Sensor Probes</strong></li>
<li><strong>Ability to View Inhibit Status from Front Screen</strong></li>
<li><strong>Max Starts</strong></li>
<li><strong>Configurable Limit for IRT</strong></li>
<li><strong>Pump Starts and Flow Based on Contactor Closure</strong></li>
<li><strong>Strings Not Included in DNP Class 0</strong></li>
<li><strong>Pulse Input Flow and Rain Gauge</strong></li>
<li><strong>Station Low Flow Rate Alarm</strong></li>
</ul>
<p><strong>Related Blogs:</strong></p>
<p><a href="http://www.multitrode.com/blog/2010/05/new-multismart-data-logger-enhancements/" target="_blank">New MultiSmart Data Logger Enhancements</a></p>
<p><a href="http://www.multitrode.com/blog/2010/05/new-alternation-by-efficiency-enhancements-in-multismart-firmware-version-2-3/" target="_blank">New Alternation by Efficiency Enhancement</a></p>
<p><a href="http://www.multitrode.com/blog/2010/05/multismart-firmware-2-3-duoprobe-features/">MultiSmart Firmware 2.3 – DuoProbe Features</a></p>
<p><a href="http://www.multitrode.com/blog/2010/05/upgrading-firmware-versions/" target="_blank">Upgrading Firmware Versions</a></p>
<p><a href="http://www.multitrode.com/blog/2010/05/downloading-firmware-upgrades/" target="_blank">Downloading Firmware Upgrades</a></p>
<p><a href="http://www.multitrode.com/blog/2010/05/sign-up-to-receive-firmware-upgrade-notifications/" target="_blank">Sign Up to Receive Firmware Upgrade Notification</a><span id="more-784"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/05/details-on-multismart-firmware-version-2-3/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New Alternation by Efficiency Enhancements in MultiSmart Firmware Version 2.3</title>
		<link>http://www.multitrode.com/blog/2010/05/new-alternation-by-efficiency-enhancements-in-multismart-firmware-version-2-3/</link>
		<comments>http://www.multitrode.com/blog/2010/05/new-alternation-by-efficiency-enhancements-in-multismart-firmware-version-2-3/#comments</comments>
		<pubDate>Fri, 14 May 2010 14:14:29 +0000</pubDate>
		<dc:creator>JimmyH</dc:creator>
				<category><![CDATA[General News]]></category>
		<category><![CDATA[Efficiency Deadband]]></category>
		<category><![CDATA[most efficient pump]]></category>
		<category><![CDATA[MultiSmart]]></category>
		<category><![CDATA[PLCs]]></category>
		<category><![CDATA[Pump Alternation Efficiency]]></category>
		<category><![CDATA[pump controllers]]></category>
		<category><![CDATA[pump efficiency]]></category>
		<category><![CDATA[Pump Station Manager]]></category>
		<category><![CDATA[RTUs]]></category>
		<category><![CDATA[Station Optimization]]></category>
		<category><![CDATA[wastewater pump stations]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=782</guid>
		<description><![CDATA[Our team of highly qualified R&#038;D engineers set their sights on addressing these shortcomings, focused on making O&#038;M jobs easier and elating our Customers.  There is we did:

MultiTrode created an Efficiency Deadband (%). This allows for a standard alternation scheme to occur whenever the efficiency of the pumps fall into the Efficiency Deadband. If the difference in efficiency exceeds the Efficiency Deadband, the station will resume the N to 1 ratio favoring the most efficient pump.
MultiTrode recommends setting the Station Optimization feature of Max Starts per Hour on each pump.
For ease of reference, a database tag was created to indicate when the regular alternation scheme is active in the Pump Alternation Efficiency Mode.]]></description>
			<content:encoded><![CDATA[<p>MultiTrode’s <a href="http://www.multitrode.com/pump-station-manager" target="_blank">MultiSmart</a> Pump Station Manager is the next generation of technology for water and wastewater pump stations – combining the best of PLCs, RTUs and pump controllers into a comprehensive and intuitive package.</p>
<p><a href="http://www.multitrode.com/pump-station-manager">MultiSmart </a>has the capability of calculating efficiency based on 3 measured variables:</p>
<ol>
<li>Supply Voltage</li>
<li>Current</li>
<li>Flow</li>
</ol>
<p>Knowing these 3 variables enables the Operator to calculate gallons per kilowatt Hr (gal/kWhr).</p>
<p>MultiSmart <a href="http://www.multitrode.com/firmware-upgrades.php" target="_blank">Firmware Version 2.3.0</a> includes a groundbreaking advancement, Alternation by Efficiency, the ingenious derivative of MultiSmart’s gal/kWhr ability!</p>
<p>In order to save energy costs, this mode is especially useful where an old pump, scheduled for replacement, is coupled with a new pump.</p>
<p><strong>The Old Way:</strong></p>
<p>Create an N to 1 ratio based on the most efficient pump, allowing the most efficient pump to run N (N is user adjustable) times more than the least efficient pump.</p>
<p><strong>The Problem:</strong></p>
<ol>
<li>Although pump efficiencies begin to equalize, the alternation mode is continues to favor one pump over the other because N to 1 is an absolute comparison.</li>
<li>When implemented, some stations experience a high number of starts per day on the most efficient pump which adversely affects the efficiency of new pumps.</li>
<li>Not all systems are set up the same. Therefore, there’s a need for indication of the currently active alternation scheme.</li>
</ol>
<p><strong>MultiTrode’s Solution:</strong></p>
<p><a href="http://www.multitrode.com/about-us.php" target="_blank">MultiTrode </a>is committed to R&amp;D, continually working on product improvement and new product developments, responding to ideas and feedback from customers.</p>
<p>Our team of highly qualified R&amp;D engineers set their sights on addressing these shortcomings, focused on making O&amp;M jobs easier and elating our Customers.  There is we did:</p>
<ol>
<li>MultiTrode created an Efficiency Deadband (%). This allows for a standard alternation scheme to occur whenever the efficiency of the pumps fall into the Efficiency Deadband. If the difference in efficiency exceeds the Efficiency Deadband, the station will resume the N to 1 ratio favoring the most efficient pump.</li>
<li>MultiTrode recommends setting the <a href="http://www.multitrode.com/blog/2009/08/pump-station-optimization-easy-to-achieve-with-multismart/" target="_blank">Station Optimization feature</a> of Max Starts per Hour on each pump.</li>
<li>For ease of reference, a database tag was created to indicate when the regular alternation scheme is active in the Pump Alternation Efficiency Mode.</li>
</ol>
<p><em>Written By:<br />
Jimmy Hidalgo<br />
MultiTrode Applications Engineer<br />
May 14, 2010</em><span id="more-782"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/05/new-alternation-by-efficiency-enhancements-in-multismart-firmware-version-2-3/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>MultiSmart Firmware 2.3 &#8211; DuoProbe Features</title>
		<link>http://www.multitrode.com/blog/2010/05/multismart-firmware-2-3-duoprobe-features/</link>
		<comments>http://www.multitrode.com/blog/2010/05/multismart-firmware-2-3-duoprobe-features/#comments</comments>
		<pubDate>Thu, 13 May 2010 15:07:40 +0000</pubDate>
		<dc:creator>Darcy Sullivan</dc:creator>
				<category><![CDATA[General News]]></category>
		<category><![CDATA[DuoProbe]]></category>
		<category><![CDATA[pressure transducer]]></category>
		<category><![CDATA[probe]]></category>
		<category><![CDATA[SCADA]]></category>
		<category><![CDATA[VFD]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=779</guid>
		<description><![CDATA[The MultiTrode DuoProbe is built on the concept of combining MultiTrode’s ultra reliable 10 Sensor Probe with the high resolution of a pressure transducer.
The DuoProbe has 10 metallic sensors, just like MultiTrode’s standard Probe, with the addition of a built-in pressure transducer integrated to the end of Probe. After initial configuration, the DuoProbe will appear [...]]]></description>
			<content:encoded><![CDATA[<p>The <a href="http://www.multitrode.com/liquid-level-probe" target="_blank">MultiTrode DuoProbe</a> is built on the concept of combining <img class="alignright size-full wp-image-778" title="DuoProbe" src="http://www.multitrode.com/blog/wp-content/uploads/2010/05/DuoProbe.jpg" alt="DuoProbe" width="135" height="232" />MultiTrode’s ultra reliable 10 Sensor Probe with the high resolution of a pressure transducer.</p>
<p>The <a href="http://www.multitrode.com/liquid-level-probe" target="_blank">DuoProbe </a>has 10 metallic sensors, just like MultiTrode’s standard Probe, with the addition of a built-in pressure transducer integrated to the end of Probe. After initial configuration, the DuoProbe will appear to operate exactly like MultiTrode’s standard <a href="http://www.multitrode.com/liquid-level-probe" target="_blank">Probe</a>. After just a few level cycles, the unit will “Auto-Calibrate” and go into High Resolution mode using its built-in pressure transducer.</p>
<p>MultiTrode’s innovative <a href="http://www.multitrode.com/pump-station-manager" target="_blank">Pump Station Manager</a> – the <a href="http://www.multitrode.com/pump-station-manager" target="_blank">MultiSmart</a> &#8211; will periodically recalibrate the DuoProbe thus ensuring accuracy. In the unlikely event the pressure transducer fails, the MultiSmart will automatically switch over to operate off the 10 Sensor Probe. The DuoProbe will only function with the MultiSmart Pump Station Manager.</p>
<p>Innovative features include:</p>
<ul>
<li>High Resolution Level reading can be very useful in VFD systems or any system where monitoring small changes in level is desirable.</li>
<li>Ability to monitor liquid after it has exceeded the top of the Probe.</li>
<li>Level can be monitored all the way to top of well even if the DuoProbe is at bottom of well enabling Operators to know the exact well level (especially significant in emergency conditions).</li>
<li>Particular useful to sites with a SCADA connection because Operators can determine which well(s) are at their highest levels and dispatch emergency generator equipment accordingly.</li>
</ul>
<p> <em>Tim Agrillo<br />
May 12, 2010</em><span id="more-779"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/05/multismart-firmware-2-3-duoprobe-features/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New MultiSmart Data Logger Enhancements</title>
		<link>http://www.multitrode.com/blog/2010/05/new-multismart-data-logger-enhancements/</link>
		<comments>http://www.multitrode.com/blog/2010/05/new-multismart-data-logger-enhancements/#comments</comments>
		<pubDate>Thu, 13 May 2010 14:49:45 +0000</pubDate>
		<dc:creator>JimmyH</dc:creator>
				<category><![CDATA[MultiTrode News]]></category>
		<category><![CDATA[Configuration Logs]]></category>
		<category><![CDATA[Crisis Logging]]></category>
		<category><![CDATA[data logger]]></category>
		<category><![CDATA[Enhanced CF Card Options]]></category>
		<category><![CDATA[Field Comments Logging]]></category>
		<category><![CDATA[Interval Logging]]></category>
		<category><![CDATA[MultiSmart]]></category>
		<category><![CDATA[Pump Station Manager]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=773</guid>
		<description><![CDATA[Noteworthy Data Logger Improvements include:
Crisis Logging - When a configurable Crisis event occurs, values of configured tags are saved to a log file for a User-programmed set of time before and after the crisis. This is an excellent troubleshooting tool. For example, if you receive a Motor Overtemp Fault, you can log the motor currents for 30 seconds before and after the fault.
Interval Logging - Specific log entries can be stored at periodic intervals. Additionally, these can be configured to trigger a DNP event. This is excellent Trend Analysis tool useful SCADA software, Excel or any trending software.
Configuration Logs - Any configuration changes are saved to the Configuration Log. If security is enabled, then the username is recorded along with the change. For security-conscious organizations, this is an indispensable security tool.
Field Comments Logging – This novel features allows you to add Comments to the History Log easily and quickly. For example, configuration changes can be accompanied by a quick note of explanation.
Enhanced CF Card Options – Save logs to a compact flash card]]></description>
			<content:encoded><![CDATA[<p>MultiTrode’s MultiSmart <a href="http://www.multitrode.com/pump-station-manager" target="_blank">Pump Station Manager</a> is the next generation of technology for water and wastewater pump stations – combining the best of PLCs, RTUs and pump controllers into a comprehensive and intuitive package.</p>
<p>MultiTrode’s commitment to R&amp;D is evidenced by the <a href="http://www.multitrode.com/pump-station-manager">MultiSmart</a> Firmware 2.3.0 Release. This groundbreaking advancement includes numerous technological achievements including data logger enhancements to ensure make accessibility even easier and capabilities even better.</p>
<p>Noteworthy<strong> Data Logger</strong> Improvements include:</p>
<ul>
<li><strong>Crisis Logging &#8211; </strong>When a configurable Crisis event occurs, values of configured tags are saved to a log file for a User-programmed set of time before and after the crisis. This is an excellent troubleshooting tool. For example, if you receive a Motor Overtemp Fault, you can log the motor currents for 30 seconds before and after the fault.</li>
<li><strong>Interval Logging &#8211; </strong>Specific log entries can be stored at periodic intervals. Additionally, these can be configured to trigger a DNP event. This is excellent Trend Analysis tool useful SCADA software, Excel or any trending software.</li>
<li><strong>Configuration Logs &#8211; </strong>Any configuration changes are saved to the Configuration Log. If security is enabled, then the username is recorded along with the change. For security-conscious organizations, this is an indispensable security tool.</li>
<li><strong>Field Comments Logging – </strong>This novel features allows you to add Comments to the History Log easily and quickly. For example, configuration changes can be accompanied by a quick note of explanation.</li>
<li><strong>Enhanced CF Card Options – </strong>Save logs to a compact flash card including:</li>
<li><em>Configuration Logs</em></li>
<li><em>Device Information Logs (including IP Address, Serial Number, Enable Code, Hardware Version, Firmware Version, DSP Version, etc.)</em></li>
<li><em>Interval Logs</em></li>
<li><em>System Logs</em></li>
<li><em>History Logs</em></li>
</ul>
<p>With such valuable information at your finger tips, determining why a specific event occurred will be as simply as reading a log… Perhaps someone changed the configuration: You can see exactly who changed what. Was there a reason for the change? Did they write a Comment? Don’t have time to deal with this now? Just save all the logs to the CF card and look at them later from the comfort of your office.</p>
<p><strong>What could be easier -</strong></p>
<p><em>Written By:<br />
Jimmy Hidalgo<br />
MultiTrode Applications Engineer<br />
May 11, 2010</em><span id="more-773"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/05/new-multismart-data-logger-enhancements/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Upgrading Firmware Versions</title>
		<link>http://www.multitrode.com/blog/2010/05/upgrading-firmware-versions/</link>
		<comments>http://www.multitrode.com/blog/2010/05/upgrading-firmware-versions/#comments</comments>
		<pubDate>Thu, 13 May 2010 14:27:42 +0000</pubDate>
		<dc:creator>Darcy Sullivan</dc:creator>
				<category><![CDATA[General News]]></category>
		<category><![CDATA[Firmware]]></category>
		<category><![CDATA[MultiSmart]]></category>
		<category><![CDATA[MultiTrode]]></category>
		<category><![CDATA[updgrade firmware]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=771</guid>
		<description><![CDATA[Using the compact flash port of your MultiSmart unit and a CF card is the easiest way to upgrade the firmware.
Simply:

Download the firmware to your computer and unzip the file.
Look for the file named update.img.
Use a flash card reader/writer to copy the file to the flash card. (You can purchase a USB compact flash reader/writer from MultiTrode or [...]]]></description>
			<content:encoded><![CDATA[<p>Using the compact flash port of your MultiSmart unit and a CF card is the easiest way to upgrade the firmware.</p>
<p>Simply:</p>
<ul>
<li>Download the firmware to your computer and unzip the file.</li>
<li>Look for the file named update.img.</li>
<li>Use a flash card reader/writer to copy the file to the flash card. (You can purchase a USB compact flash reader/writer from MultiTrode or other sources.)</li>
<li>Insert the compact flash card into the MultiSmart unit and restart (press Settings-&gt;More-&gt;More-&gt;Restart).</li>
<li>The unit will use the upgrade image to save the latest firmware automatically</li>
<li>Press the yellow &#8220;Save CF Data&#8221; button on your MultiSmart unit <em>before</em> ejecting the CF card. Failure to do so may result in data corruption and/or damage to the CF card.</li>
<li>We recommend that you erase the update.img file from the CF card after upgrading all units that you need to upgrade. </li>
</ul>
<p><span id="more-771"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/05/upgrading-firmware-versions/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Downloading Firmware Upgrades</title>
		<link>http://www.multitrode.com/blog/2010/05/downloading-firmware-upgrades/</link>
		<comments>http://www.multitrode.com/blog/2010/05/downloading-firmware-upgrades/#comments</comments>
		<pubDate>Thu, 13 May 2010 14:25:59 +0000</pubDate>
		<dc:creator>Darcy Sullivan</dc:creator>
				<category><![CDATA[MultiTrode News]]></category>
		<category><![CDATA[Firmware]]></category>
		<category><![CDATA[firmware upgrades]]></category>
		<category><![CDATA[MultiSmart]]></category>
		<category><![CDATA[MultiTrode]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=769</guid>
		<description><![CDATA[If you haven&#8217;t created a user account, please take a few moments to do by clicking on the Sign Up box in the top right of the multitrode.com homepage.
When you get to the Newsletter Signup section, don’t forget to select the box reading “Please give me access to the free MultiSmart firmware upgrades and release information.”
Your [...]]]></description>
			<content:encoded><![CDATA[<p>If you haven&#8217;t created a user account, please take a few moments to do by clicking on the Sign Up box in the top right of the<a href="http://www.multitrode.com" target="_blank"> multitrode.com homepage.</a></p>
<p>When you get to the <a href="http://www.multitrode.com/member-registration.php" target="_blank">Newsletter Signup section</a>, don’t forget to select the box reading “Please give me access to the free MultiSmart firmware upgrades and release information.”</p>
<p>Your request will be processed within 24 hours.</p>
<p>If you already have a user account, and are logged in, you will see &#8220;Edit my account details&#8221; at the top right of the web page. Click on this, and check the box which reading “Please give me access to the free MultiSmart firmware upgrades &amp; release information.”</p>
<p> Complete the other details requested and click the Submit button. Your request will be processed within 24 hours.<span id="more-769"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/05/downloading-firmware-upgrades/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Sign Up to Receive Firmware Upgrade Notifications</title>
		<link>http://www.multitrode.com/blog/2010/05/sign-up-to-receive-firmware-upgrade-notifications/</link>
		<comments>http://www.multitrode.com/blog/2010/05/sign-up-to-receive-firmware-upgrade-notifications/#comments</comments>
		<pubDate>Thu, 13 May 2010 14:11:28 +0000</pubDate>
		<dc:creator>Darcy Sullivan</dc:creator>
				<category><![CDATA[MultiTrode News]]></category>
		<category><![CDATA[Firmware]]></category>
		<category><![CDATA[MultiTrode]]></category>

		<guid isPermaLink="false">http://www.multitrode.com/blog/?p=762</guid>
		<description><![CDATA[Software upgrades can be downloaded from MultiTrode’s website.
If you haven’t already registered, all you have to do is click on the Sign Up box in the top right of the multitrode.com homepage:
 
When you get to the Newsletter Signup section, don’t forget to select the box reading “Please give me access to the free MultiSmart firmware [...]]]></description>
			<content:encoded><![CDATA[<p>Software upgrades can be downloaded from <a href="http://www.multitrode.com" target="_blank">MultiTrode’s website</a>.</p>
<p>If you haven’t already registered, all you have to do is click on the Sign Up box in the top right of the multitrode.com homepage:</p>
<p style="TEXT-ALIGN: center"> <img class="size-medium wp-image-763  aligncenter" title="sign_up1" src="http://www.multitrode.com/blog/wp-content/uploads/2010/05/sign_up1-300x147.jpg" alt="sign_up1" width="300" height="147" /></p>
<p style="text-align: left;">When you get to the Newsletter Signup section, don’t forget to select the box reading “Please give me access to the free MultiSmart firmware upgrades and release information.”</p>
<p style="text-align: center;"> <a href="http://www.multitrode.com/member-registration.php"><img class="size-medium wp-image-764   aligncenter" title="sign_up2" src="http://www.multitrode.com/blog/wp-content/uploads/2010/05/sign_up2-300x265.jpg" alt="sign_up2" width="300" height="265" /></a></p>
<p>If you have already registered and didn’t select this option – but you want access to MultiSmart firmware, simply email <a href="mailto:marketing@multitrode.com">marketing@multitrode.com</a> requesting an upgrade.  Please include a phone number where we can contact you.<span id="more-762"></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.multitrode.com/blog/2010/05/sign-up-to-receive-firmware-upgrade-notifications/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

